LBFS-01111.0
Point level detection based on frequency sweep technology
( No Reviews )
£ 196.80
Seller LNT GLOBAL LTD
Add FAQ
Performance characteristics
- Measuring principle
-
- CleverLevel level switches (Frequency Sweep)
- Media characteristics
-
- DC > 1.5
- Hysteresis
-
- ± 1 mm
- Repeatability
-
- ± 1 mm
- Step response time
-
- 0.1 s , typ.
- 0.2 s , max.
- Damping
-
- 0 … 10 s , adjustable
Process connection
- Wetted parts material
-
- PEEK Natura
- AISI 316L (1.4404)
- AISI 304 (1.4301), optional
- Surface roughness wetted parts
-
- Ra ≤ 0.8 µm
Output signal
- Output type
-
- PNP
- NPN
- Switching logic
-
- Normally closed (NC)
- Normally open (NO)
Compliance and approvals
- EMC Emission
-
- EN 61326, installed in a closed metal tank
- EMC Immunity
-
- EN 61326, installed in a closed metal tank
- Hygiene
-
- Refer to section "Compliance and approvals"
- Railway applications
-
- EN 50155
- Safety
-
- cULus listed, E365692
- WHG (overfill, leakage)
- Explosion protection
-
- ATEX II 1D Ex ta IIIC T100 °C Da
- ATEX II 1G Ex ia IIC T4/T5 Ga
- ATEX II 3G Ex ec IIC T4/T5 Gc
No FAQs Found